WATER/WATER HEAT PUMP
OCHSNER GEO SEAL
Due to its consistently high source temperatures of between 8 and 12 °C, regardless of weather conditions or the season, groundwater is considered the most efficient heat source. With the GEO SEAL series, OCHSNER uses this heat source for heating, hot water preparation and passive cooling. It is inverter-controlled and uses the R290 refrigerant. GEO SEAL combines high efficiency with convenient operation and flexible applications, whether in a single-family or two-family home or as a floor station in buildings with many residential units.



OCHSNER safety concept
The use of R290 is subject to special safety requirements. The OCHSNER safety concept therefore continuously monitors the interior of the unit and detects even small amounts of escaping refrigerant. In the event of a leak, the system responds automatically: the compressor is stopped and an integrated fan directs the refrigerant outside in a controlled manner.
Additional safety components, such as check valves and safety valves, gas separators and collection systems, complement the multi-stage protection concept. All functions are integrated directly into the heat pump and operate automatically, without any additional operating effort.

User-friendly touch display, Modbus interface and app
Control is provided by OCHSNER Tronic Fox (OTF), with operation available either via the heat pump’s touch display or using the OCHSNER Easy App. The Modbus interface enables straightforward integration into building management systems or smart home systems. For particularly low energy costs, the heat pumps are SG-ready and can use solar power and the intelligent power grids of the future.

For new builds and renovations in single-family or multi-family homes
Flow temperatures of up to 70 °C also make the series suitable for operation with radiators. The units can also be connected in cascades of up to six for higher requirements. Particularly in multi-family properties, the compact dimensions allow available space to be used optimally.

Multi-stage output adjustment
The intelligent inverter technology with a 12-stage inverter automatically adjusts the output to the building’s actual heat demand. This means the heat pump provides exactly as much output as is currently required.

Heating, hot water and cooling
In summer, the heat source can also be used for passive cooling with optional accessories. Taking the required heating capacity into account, the heat pump can easily be upgraded for year-round pool heating.

Model variety for groundwater as a heat source
The GEO SEAL series is available in two output sizes for buildings with heating loads between 2 and 13 kW and uses the R290 refrigerant.
Frequently asked questions about OCHSNER GEO SEAL
Groundwater maintains a constant temperature of 8 to 12 °C throughout the year, regardless of the outside temperature or season. This small temperature difference to the desired heating temperature significantly reduces the heat pump’s energy requirements. As a result, GEO SEAL achieves SCOPs of 6.79 to 6.88, depending on the model, and ensures the lowest heating costs.
No. Thanks to inverter technology, GEO SEAL continuously adapts to the current heat demand, so an additional buffer storage tank is not required. This saves space, installation effort and costs.
Yes. Passive cooling is possible with optional additional equipment.
According to the ErP label, the sound power level is between 38 and 40 dB(A), depending on the model. This allows installation in hallways, utility rooms or ancillary rooms – directly inside the residential building, without disruptive noise.
R290 is propane – a natural refrigerant with very low global warming potential. It operates with high thermodynamic efficiency and is not synthetically produced. GEO SEAL uses R290 exclusively.
The Tower S200 combines a heat pump and hot water storage tank in a compact unit with a footprint of less than 0.5 m². The S1 indoor unit does not have its own storage tank; it is used where hot water preparation is provided via a separate storage tank. The suitable version depends on the available space and the planned hydraulic system.
Several requirements must be met to use groundwater as a heat source: a sufficient quantity of water, a water quality analysis, a water law permit issued by the responsible authority, and the construction of extraction and reinjection wells. The well builder, drilling company or OCHSNER System Partner can provide support with the permit application.
Helpful Links



