Air - Water

OCHSNER AIR HAWK 726

18 - 22 kW

The high end heat pump is suitable for buildings with heat loads between 18 and 22 kW; higher outputs are also possible with a cascade. It works with a speed controlled compressor and delivers heat and DHW up to 65°C. It can also be used for energy saving surface cooling and for active air conditioning and room dehumidification via fan coils. The AIR HAWK 726 features an impressive SCOP that puts it ahead of the competition (above 5 at 35°C flow temperature), as well as extremely quiet operation of the two powerful fans in the bench evaporator outdoor unit. This makes it the perfect solution even in high-density residential areas. The slimline indoor unit has a footprint of less than half a square metre. It is controlled with the leading-edge Ochsner Tronic Smart (OTS) and can be operated either on the 7" touchscreen of the heat pump indoor unit or using the OCHSNER Smart app. The AIR HAWK series was honoured with the Plus X Award in the categories innovation, high quality, ease of use, functionality and ecology.

Climate zone (middle)
Energy efficient
A+++Energy efficiency class (D to A+++)
17 kWP rated
198.6 %Efficiency ETAs
31.6 dB(A)Sound pressure level (at 3 m)

Suitable for

Detached and two-family houses
Underfloor heating
Radiators up to 60°C

Technical details AIR HAWK 726

A7/W35

Heating output (EN14511)
9.25 kW
Power consumption (EN14511)
1.80 kW
Coefficient of performance COP (EN14511)
5.14

Energy efficiency (average climate zone)

at max. flow temperature (heating)
35 °C
Energy efficiency class (D to A+++)
A+++
P rated
17 kW
Efficiency ETAs
198.6 %
SCOP
5.04

Indoor unit

Dimensions (HxWxD)
1287x600x680 mm
Weight (excl. packaging)
173 kg

Outdoor unit

Dimensions (HxWxD)
1262x2224x965 mm
Weight (excl. packaging)
140 kg
Sound pressure level (at 3 m)
31.6 dB(A)
Sound power level (EN12102)
49 dB(A)

Electrical data

Phases/nominal voltage/frequency
3/~380-400/50 ~/V/Hz
Variable speed compressor
Refrigerant R32
Heating or heating/cooling
Max. Vorlauftemp. 65 °C65 °C Max. flow temp.
OTS-ReglerOTS controller
SG Ready

OCHSNER AIR HAWK More models of the series

AIR HAWK 208

6 - 10 kW
AIR HAWK 208
incl. horizontal split evaporatorRefrigerant R513AOTS controller
Energy efficiencyA+++
P rated6 kW
Efficiency175.2 %
Lₚ at 3 m28 dB(A)
65 °C Max. flow temp. | OTS controller | SG-Ready

AIR HAWK 518

9 - 14 kW
AIR HAWK 518
incl. horizontal split evaporatorRefrigerant R32OTS controller
Energy efficiencyA+++
P rated12 kW
Efficiency198.7 %
Lₚ at 3 m35.5 dB(A)
65 °C Max. flow temp. | OTS controller | SG-Ready

AIR HAWK 616

6 - 16 kW
AIR HAWK 616
incl. horizontal split evaporatorRefrigerant R32OTS controller
Energy efficiencyA+++
P rated13 kW
Efficiency197.7 %
Lₚ at 3 m35.7 dB(A)
65 °C Max. flow temp. | OTS controller | SG-Ready

AIR HAWK 1850

24 - 51 kW
AIR HAWK 1850
incl. v-split evaporatorRefrigerant R32OTS controller
Energy efficiencyA+++
P rated40 kW
Efficiency186.3 %
Lₚ at 3 m39.7 dB(A)
60 °C Max. flow temp. | OTS controller | SG-Ready